Torque Auditing Examples

Since this tool incorporates a built-in transducer, it is a simple matter to connect a monitoring device and electronically capture the peak torque seen during each installation cycle.

The data collector can capture the peak torque values seen during multiple installations.

Once collected, this data can then be processed to yield a picture (histogram) of the 6 sigma torque scatter for the tool.

The data collector can then compare this 6 sigma distribution to the high and low specification limits the tool was adjusted to work within.